Original Article
Balaji SA1, Shekar Shobana*,2, Sunderesan Balagopal3, Akshaya N4, Sarath Kumar5, Ayisha M6,

1Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India.

2Dr. Shekar Shobana MDS, Reader, Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India. E-mail: drshobana.bds@gmail.com

3Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India.

4Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India.

5Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India.

6Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India.

*Corresponding Author:

Dr. Shekar Shobana MDS, Reader, Department of Conservative Dentistry and Endodontics, Tagore Dental College and Hospital, Chennai, India. E-mail: drshobana.bds@gmail.com, Email: drshobana.bds@gmail.com
Received Date: 2023-05-02,
Accepted Date: 2023-05-09,
Published Date: 2023-07-31
Year: 2023, Volume: 13, Issue: 3, Page no. 120-125, DOI: 10.26463/rjms.13_3_7
Views: 1316, Downloads: 40
Licensing Information:
CC BY NC 4.0 ICON
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0.
Abstract

Aim: The aim of the present study was to compare and evaluate contact angle and surface roughness of two resin based dental composites with different filler composition after finishing and polishing.

Methodology: Twenty four composite cylinders measuring 6x2 mm were made using Teflon moulds [Group 1 (n=12) – Ivoclar tetric N ceram nanohybrid, Group 2 (n=12) - Ivoclar te Econom plus]. Composite surfaces were polished with silicon carbide abrasives and subjected to surface roughness analysis using a stylus profilometer and contact angle measurement using goniometer.

Results: The surface roughness was significantly higher in Group 2 than the Group 1 (Ra and Rq – p <0.001). There was no statistically significant difference in the contact angle values between Group 1 and Group 2 (p=0.582).

Conclusion: Finishing and polishing of composites provide better surface characteristics and optimal surface wettability in both nanohybrid and microhybrid composites. Nanohybrid composites were found to have lower surface roughness than microhybrid composites.

<p><strong>Aim: </strong>The aim of the present study was to compare and evaluate contact angle and surface roughness of two resin based dental composites with different filler composition after finishing and polishing.</p> <p><strong>Methodology: </strong>Twenty four composite cylinders measuring 6x2 mm were made using Teflon moulds [Group 1 (n=12) &ndash; Ivoclar tetric N ceram nanohybrid, Group 2 (n=12) - Ivoclar te Econom plus]. Composite surfaces were polished with silicon carbide abrasives and subjected to surface roughness analysis using a stylus profilometer and contact angle measurement using goniometer.</p> <p><strong>Results:</strong> The surface roughness was significantly higher in Group 2 than the Group 1 (Ra and Rq &ndash; p &lt;0.001). There was no statistically significant difference in the contact angle values between Group 1 and Group 2 (p=0.582).</p> <p><strong> Conclusion: </strong>Finishing and polishing of composites provide better surface characteristics and optimal surface wettability in both nanohybrid and microhybrid composites. Nanohybrid composites were found to have lower surface roughness than microhybrid composites.</p>
Keywords
Nanohybrid composite, Microhybrid composite, Finishing and polishing, Surface roughness, Contact angle, Stylus profilometer, Goniometer
Downloads
  • 1
    FullTextPDF
Article
Introduction

Clinicians routinely utilise dental composite resins as restorative materials. They are esthetic, offer easy application, economic, and have the potential to replace amalgam in terms of strength and longevity. Dental composites are primarily made of organic resin matrix, fillers (either organic or inorganic), initiators, and accelerators.1 The four types of resin composites hybrid, microfilled, microhybrid, and nanofilled composites can be categorised according to the size of the filler particles. In contrast to macrofilled composites which are used in areas where strength is the primary concern, microfilled and nanofilled materials are highly concerned with aesthetics.2,3 Both anterior and posterior teeth serve better with composite restorations.4 After ten years, the overall survival percentage for composite restorations is 75.6%.5 Color change, fracturing, and marginal degeneration resulting in secondary caries are the most frequent factors requiring replacement of composite restorations.6 The last stage of finishing and polishing is crucial for composite restorations' aesthetics and bio-integration. Finishing and polishing of restorations enhances appearance and protects patient's oral health.7,8 Increased microleakage can result in sensitivity, discoloration at restoration margins, and the development of secondary caries.9 Multi-step discs, fine and superfine diamond burs, abrasive discs, diamond, silicon or aluminium oxide impregnated soft rubber cups are some of the polishing technologies that are available.10

Increased surface roughness enhances bacterial adhesion, according to in vitro studies.11 Cell adhesion properties of biomaterials can be modulated by altering the surface properties of biomaterials. The wettability of solid surfaces is a different surface characteristic that is measured by the contact angle. The measurement of contact angles (ca) also enables the determination of surface free energies (SFE), which reveals the polarity or non-polarity of the interactions at the liquid/solid interface as well as the hydrophilicity or hydrophobicity of a surface.12,13 Compared to hydrophobic surfaces, hydrophilic surfaces with high surface free energy values are more likely to exhibit bacterial adherence.14 In order to evaluate the two different filled resin-based dental composites, the contact angle and surface roughness both before and after finishing and polishing were assessed.

Materials and Method

Sample size calculation

Sample size was calculated with G power software version 3.1.9, with 80% power, keeping the level of significance at 5%, and effect size of 0.5 as 12 samples per group.

Specimens preparation

For surface roughness and contact angle analysis Twenty four composite slabs were prepared using Teflon moulds in dimensions of 6 mm in diameter and 2 mm in height. The composite blocks were polished using silicon carbide and aluminium oxide abrasives (Shofu mini snap kit, Japan) in the following order: coarse, medium, fine, and super fine.

The samples were divided into the following groups: (Table 1)

Group I (NH): Nanohybrid composite resin (Ivoclar tetric N ceram) (n=12)

Group II (MH): Microhybrid composite resin (Ivloclar Te-Econom Plus ) (n= 12) The samples were stored in light-proof container and subjected to surface roughness analysis using a stylus profilometer (Mitutoyo version 2.0) and contact angle measurement using a goniometer (Sessile drop method).

Statistical analysis

The data were tabulated on Excel sheet and statistically analysed using IBM SPSS software version 22. Test of normality was done using Kolmogorov-Sminrov test and data were found to be normal in distribution. Inter group comparison was done using independent t-test. Intra group comparison was done using paired t-test.

Results

Surface Roughness Analysis

Ra – Intergroup comparison

There was no significant difference in the Ra values of unpolished surfaces between nanohybrid and microhybrid composites (p=0.301).

There was a statistical significant difference in the Ra values of polished surfaces between nanohybrid and microhybrid composites (p <0.001) (Table 2).

Ra – Intragroup comparison

There was a statistical significant difference in the Rq values of group 1 and group 2 between unpolished and polished surfaces (p=0.001 and p=0.03, respectively) (Table 3).

Rq – Intergroup comparison

There was a statistical significant difference in the Rq values of both the unpolished and polished surfaces between group 1 and group 2 (p=0.024 and p <0.001, respectively) (Table 2).

Rq – Intragroup comparison

There was no statistical significant difference in the Rq values of group 1 and group 2 between unpolished and polished surfaces (p=0.620 and p=0.944, respectively) (Table 3).

Contact Angle Analysis

Intergroup comparison

There was no statistical significant difference in the contact angle of both the unpolished and polished surfaces between group 1 and group 2 (p=0.076 and p=0.582, respectively) (Table 4).

Intragroup comparison

There was no statistical significant difference in the contact angle of group 1 and group 2 between unpolished and polished surfaces (p=0.265 and p=0.821, respectively ) (Table 5).

Discussion

Finishing and polishing continues to be the most neglected part of composite restoration despite the researchers emphasising its significance. According to a study, 99% of dental clinicians understand the value of polishing and finishing composites but only 59.8% of practitioners use the proper protocol of finishing and polishing.15 The particle size, shape, filler, and resin utilised, together with the polishing mechanism, are some of the variables that determine the polishability of composite resin.

Microhybrid composites and nanocomposites are two types of commonly used direct composite resin materials based on filler content. Microhybrid composites consist of both microscale and nanoscale (~20 nm) glass fillers, while nanocomposites are made of either individual (5– 20 nm) or clustered (0.6–1.4 μm) nanoscale glass fillers.16 Tetric N ceram comprises of Barium glass, ytterbium triflouride, 80-81 wt% mixed oxide and copolymers, whereas Te Econom Plus contains Barium glass, Barium-Aluminium fluoro-silicate glass, ytterbium trifluoride, highly dispersed silicon dioxide and spheroid mixed oxide (81 wt%).17

In the current investigation, contact stylus profilometer was used to assess the specimens for surface roughness. Low surface roughness improves the aesthetic appearance and endurance of the restoration in the oral environment, whereas rough surfaces encourage the buildup of plaque, jeopardize periodontal health, and result in discoloration.10 One of the key elements affecting the restoration's aesthetic performance, increasing plaque buildup, and biofilm formation is the resin composite's surface roughness.18 Even though the surface roughness of both nanohybrid and microhybrid composites were similar before polishing, finishing and polishing rendered the nanohybrid surface smoother than microhybrid.

Goniometer was used to quantify the specimen contact angles using the sessile drop method. Contact angle is a crucial factor in determining the wettability of dental materials. Surface wettability is a crucial factor in predicting the capacity of microbial adsorption and colonisation on the composite surface in a biological environment.19 The most accurate way to assess the hydrophobicity of cell surfaces is probably using the contact angle method, which is derived from drop profile image analysis.20 The hydrophilic/hydrophobic makeup of the composite surface affects the contact angle as well. Plaque buildup is reduced in proportion to observed contact angle. While polishing removes minor imperfections, finishing removes a significant amount of material.21

A study conducted by Xu L, Siedlecki CA showed that for polymers, contact angles between 40° and 70° are reported as most suitable for cell adhesion. In our study, the contact angle values obtained where within the agreeable range for both nanohybrid and microhybrid composites.22

Composite resins must be able to be polished since a smooth surface improves the restoration's aesthetics and patient comfort.23 The hydrophilic/hydrophobic makeup of the composite surface affects the contact angle as well. Plaque buildup is reduced in proportion to observed contact angle. The abrasive particle and polishing technique, both have a significant impact on the final result. Modern resin-based composite materials can be polished using a variety of methods, such as multistep discs, fine and superfine diamond burs, abrasive discs, and soft rubber cups that have been infused with diamond, silicon, or aluminium oxide. While some polishing systems are simpler and need fewer therapeutic processes, others demand more time and a series of abrasive tools that must be used sensibly.24 The abrasive particles need to be comparatively tougher than the fillers for a polishing system to work well. In the alternative, the polishing chemical will only remove the soft resin matrix, leaving the filler particles sticking out of the surface.25

According to the present study findings, composites surface characteristics improved with finishing and polishing, and their surface roughness decreased by surface wettability. It is important not to undervalue the importance of finishing and polishing of composites because these processes are an essential component of the restoration.

Conclusion

Nanohybrid composites owing to their smaller filler particle size renders high polishability to the resin composites making them ideal material of choice for restoration in the aesthetic zone. The surface wettability of both nanohybrid and microhybrid were not different from each other. The long term effects of these surface characteristics is a subject for future research.

Conflicts of Interest

Nil

Supporting File
References
  1. Zhou X, Huang X, Li M, Peng X, Wang S, Zhou X, et al. Development and status of resin composite as dental restorative materials. J Appl Polym Sci 2019;136:48180.
  2. Ilie N, Hickel R. Resin composite restorative materials. Aust Dental J 2011;56:59–66.
  3. Tanthanuch S, Kukiattrakoon B, Siriporananon C, Ornprasert N, Mettasitthikorn W, Likhitpreeda S, et al. The effect of different beverages on surface hardness of nanohybrid resin composite and giomer. J Conserv Dent 2014;17:261–265.
  4. Kodzaeva ZS, Turkina AY, Doroshina VY. The long-term results of teeth restoration with composite resin materials: a systematic literature review. Stomatologiia (Mosk) 2019;98:117-22.
  5. Dietschi D, Shahidi C, Krejci I. Clinical performance of direct anterior composite restorations: a systematic literature review and critical appraisal. Int J Esthet Dent 2019;14:252-70.
  6. Attar N. The effect of finishing and polishing procedures on the surface roughness of composite resin materials. J Contemp Dent Pract 2007;8: 27-35.
  7. Rodrigues-Junior SA, Chemin P, Piaia PP, Ferracane JL. Surface roughness and gloss of actual composites as polished with different polishing systems. Oper Dent 2015;40:418-29.
  8. Jones CS, Billington RW, Pearson GJ. The in vivo perception of roughness of restorations. Br Dent J 2004;196:42-5.
  9. Jefferies SR. Abrasive finishing and polishing in restorative dentistry: a state-of-the-art review. Dent Clin N Am 2007;51:379–397.
  10. Lopes GC, Vieira LC, Araujo E. Direct composite resin restorations: A review of some clinical procedures to achieve predictable results in posterior teeth. J Esthet Restor Dent 2004;16:19-32.
  11. Yoda I, Koseki H, Tomita M, Shida T, Horiuchi H, Sakoda H, et al. Effect of surface roughness of biomaterials on Staphylococcus epidermidis adhesion. BMC Microbiol 2014;14:1–7.
  12. Lam CNC, Kim N, Hui D, Kwok DY, Hair ML, Neumann AW. The effect of liquid properties to contact angle hysteresis. Colloids Surf 2001;189:265–278.
  13. Cazzaniga G, Ottobelli M, Ionescu A, GarciaGodoy F, Brambilla E. Surface properties of resinbased composite materials and biofilm formation: A review of the current literature. Am J Dent 2015;28:311–320.
  14. Song F, Koo H, Ren D. Effects of material properties on bacterial adhesion and biofilm formation. J Dent Res 2015;94:1027–1034.
  15. Vishwanath S, Kadandale S, Kumarappan SK, Ramachandran A, Unnikrishnan M, Nagesh HM. Finishing and polishing of composite restoration: assessment of knowledge, attitude and practice among various dental professionals in India. Cureus 2022;14(1):e20887.
  16. Kruzic JJ, Arsecularatne JA, Tanaka CB, Hoffman MJ, Cesar PF. Recent advances in understanding the fatigue and wear behaviour of dental composites and ceramics. J Mech Behav Biomed Mater 2018;88:504–33. 
  17. Kiran KV, Tatikonda A, Jhajharia K, Raina S, Lau H, Katare D, et al. In vitro evaluation of the compressive strength of microhybrid and nanocomposites. J Oral Health Dent Manage 2014;13(4):1171-73. 
  18. Baseren M. Surface roughness of nanofill and nanohybrid composite resin and ormocer-based tooth-colored restorative materials after several finishing and polishing procedures. J Biomater Appl 2004;19:121–134. 
  19. Katsikogianni, M. and Missirlis, Y. (2004) Concise Review of Mechanisms of Bacterial Adhesion to Biomaterials and of Techniques Used in Estimating Bacteria-Material Inter actions. European Cells & Materials, 8, 37-57.https://doi. org/10.22203/eCM.v008a05.
  20. Rinastiti M. Contact angle measurement of dental restorative materials by drop profile image analysis. J Teknosains 2014;3(2):81-166.
  21. Chour RG, Moda A, Arora A, Arafath MY, Shetty VK, Rishal Y. Comparative evaluation of effect of different polishing systems on surface roughness of composite resin: an in vitro study. J Int Soc Prev Community Dent 2016;6:S166–S170.
  22. Xu LC, Bauer JW, Siedlecki CA. Proteins, platelets, and blood coagulation at biomaterial interfaces. Colloids Surf B Biointerfaces. 2014 Dec 1;124:49- 68. doi: 10.1016/j.colsurfb.2014.09.040. Epub 2014 Sep 28. PMID: 25448722; PMCID: PMC5001692.
  23. Augusto MG, de Andrade GS, Caneppele TMF, Borges AB, Torres CRG. Nanofilled bis-acryl composite resin materials: is it necessary to polish? J Prosthet Dent 2020;19:30230–30234.
  24. Daud A, Adams AJ, Shawkat A, Gray G, Wilson NHF, Lynch CD, et al. Effects of toothbrushing on surface characteristics of microhybrid and nanofilled resin composites following different finishing and polishing procedures. J Dent 2020;99:103376.
  25. Tjan AHL, Chan CA. The polishability of posterior composites. J Prosthet Dent 1989;61:138–146.